Questions and Answers

  • S
    Stephanie JacksonSep 18, 2025
    What does 'FILL ERROR' mean on my FBD Beverage Dispenser and how can I fix it?
    • M
      Mary MorrisSep 18, 2025
      The 'FILL ERROR' message on your FBD Beverage Dispenser indicates that a barrel is not filling with product correctly. Run the fill circuit diagnostic sequence to troubleshoot this issue.
  • A
    Alexander HendersonAug 25, 2025
    What to do if my FBD Beverage Dispenser displays error #020: CO2 Out?
    • J
      jayalaAug 25, 2025
      If your FBD Beverage Dispenser shows error #020 indicating 'CO2 Out', it means the CO2 pressure is less than 45 PSIG (310 kPag). To resolve this: * Replace or refill the CO2 tank. * Ensure the CO2 shutoff valve at the back of the dispenser is not turned off. * Make sure the CO2 pressure transducer is properly connected and functioning. * Verify the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag), and adjust the regulator if needed.
  • H
    housematthewAug 25, 2025
    What does error #030: Water Out mean on my FBD Beverage Dispenser and how to fix it?
    • J
      Joyce Guzman DVMAug 26, 2025
      Error #030 'Water Out' on your FBD Beverage Dispenser indicates that the water pressure is less than 45 PSIG (310 kPag). Here’s how to troubleshoot: * Ensure the water line to the dispenser is on and the water shutoff at the solution module is turned on. * Check that the gas supply line is connected to the water pump and the pump is not stalled. * Verify the gas supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed. * Confirm the water pressure transducer is connected and working properly.
  • A
    Ashley BlackwellAug 27, 2025
    What does error #430: Gas #2 - CO2 Out mean on my FBD Beverage Dispenser and how to solve it?
    • J
      Jose McgeeAug 27, 2025
      Error #430 'Gas #2 - CO2 Out' on your FBD Beverage Dispenser indicates that the CO2 pressure is less than 45 PSIG (310 kPag). To solve it: * Replace or refill the CO2 tank. * Ensure the CO2 shutoff valve at the back of the dispenser is not turned off. * Ensure the CO2 pressure transducer is connected and working properly. * Ensure the CO2 supply pressure at the dispenser is reading 70 PSIG (483 kPag). Adjust the regulator if needed.
  • D
    danielsmeganSep 22, 2025
    What does 'HIGH BARREL PRESSURE' mean on my FBD Beverage Dispenser and how can I fix it?
    • H
      Haley WalkerSep 22, 2025
      The 'HIGH BARREL PRESSURE' message on your FBD Beverage Dispenser means that the barrel pressure exceeds 55 PSIG (379 kPag). Dispense a drink to reduce the barrel pressure.
  • A
    Alicia MasonSep 23, 2025
    What does Error #090: Hot Product Detected mean for my FBD Beverage Dispenser?
    • A
      Anna ThompsonSep 23, 2025
      Error #090 'Hot Product Detected' on your FBD Beverage Dispenser means that the system shut down because product in a barrel exceeds 90° F (32.2° C). Check the return temperature sensor for proper operation. If hot product was detected, call FBD for technical assistance.
  • H
    herreraericaSep 9, 2025
    What should I do if my FBD Beverage Dispenser displays Error #070: Compressor Ran Too Long?
    • R
      Rebecca ColonSep 10, 2025
      If your FBD Beverage Dispenser displays Error #070 'Compressor Ran Too Long', it means the compressor ran continuously for more than 90 minutes. Here's what you can do: * If the location is an extreme volume venue such as a festival, contact FBD service for instructions on adjusting the timer. * Run the refrigeration diagnostic sequence to determine the reason for the failure.
  • D
    David McintoshSep 12, 2025
    What does error #450: Gas #1 - High Regulated CO2 PSI mean on my FBD Beverage Dispenser and how to resolve it?
    • S
      Sharon ScottSep 12, 2025
      Error #450 'Gas #1 - High Regulated CO2 PSI' on your FBD Beverage Dispenser indicates that the regulated CO2 pressure is above 70 PSIG (483 kPag). Check the 'Gas 1' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).
  • R
    Reginald WeaverSep 3, 2025
    What does error #460: Gas #1 - Low Regulated N2 PSI mean on my FBD Beverage Dispenser and how to fix it?
    • S
      susan84Sep 3, 2025
      Error #460 'Gas #1 - Low Regulated N2 PSI' on your FBD Beverage Dispenser means that the regulated N2 pressure dropped below 50 PSIG (345 kPag). To fix it: * Ensure the N2 supply is not low. * Check the 'Gas 1' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).
  • R
    Ryan DavisSep 1, 2025
    What to do if my FBD Beverage Dispenser shows Error #390: No ADA Keypad Detected?
    • A
      Alexander ReynoldsSep 1, 2025
      If your FBD Beverage Dispenser displays Error #390 indicating 'No ADA Keypad Detected', it means the ADA keypad is missing, disconnected, or damaged. To resolve this: * Ensure the ADA keypad has no visible damage. * Ensure the keypad connector is plugged in correctly, making sure that the arrows on each connector align. * Replace the keypad if faulty.