Questions and Answers

  • D
    Donna ValenciaSep 12, 2025
    What to do if my FBD Beverage Dispenser shows Error #130: Board Failure?
    • D
      Dale HenrySep 12, 2025
      If your FBD Beverage Dispenser displays Error #130 indicating 'Board Failure', where the control board is not functioning properly, you can try the following: * Cycle the power to the dispenser to see if it will clear the error. * Replace the control board.
  • D
    David McintoshSep 12, 2025
    What does error #450: Gas #1 - High Regulated CO2 PSI mean on my FBD Beverage Dispenser and how to resolve it?
    • S
      Sharon ScottSep 12, 2025
      Error #450 'Gas #1 - High Regulated CO2 PSI' on your FBD Beverage Dispenser indicates that the regulated CO2 pressure is above 70 PSIG (483 kPag). Check the 'Gas 1' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).
  • H
    herreraericaSep 9, 2025
    What should I do if my FBD Beverage Dispenser displays Error #070: Compressor Ran Too Long?
    • R
      Rebecca ColonSep 10, 2025
      If your FBD Beverage Dispenser displays Error #070 'Compressor Ran Too Long', it means the compressor ran continuously for more than 90 minutes. Here's what you can do: * If the location is an extreme volume venue such as a festival, contact FBD service for instructions on adjusting the timer. * Run the refrigeration diagnostic sequence to determine the reason for the failure.
  • J
    Jennifer RothSep 8, 2025
    What does error #200: Return Temperature Sensor mean on my FBD Beverage Dispenser and how do I fix it?
    • M
      Mark MuellerSep 8, 2025
      Error #200 'Return Temperature Sensor' on your FBD Beverage Dispenser indicates that the refrigeration return (suction) temperature sensor is not reading correctly. To fix it: * Ensure the temperature sensor is plugged in. * Replace the sensor if faulty.
  • B
    Brianna StarkSep 7, 2025
    What does error #190: HPSI Transducer mean on my FBD Beverage Dispenser and how can I resolve it?
    • G
      Gavin HaneySep 7, 2025
      Error #190 'HPSI Transducer' on your FBD Beverage Dispenser indicates that the high side refrigeration pressure is not reading correctly. To resolve this: * Ensure the pressure transducer is plugged in. * Replace the transducer if faulty.
  • M
    Matthew MorrisAug 23, 2025
    What to do if the FBD Beverage Dispenser shows 'Syrup Out' error #011, 012, 013, 014?
    • C
      Chris YoungAug 23, 2025
      If the FBD Beverage Dispenser displays a 'Syrup Out' error, it indicates that the syrup pressure is less than 45 PSIG (310 kPag), especially for the base syrup in multi-flavor dispensers. Here's what you should do: * Replace the empty BIB (Bag-In-Box). * Ensure the gas line is properly connected to the BIB pump. * Check that the BIB pump is operating correctly. * Make sure the gas tank is not empty. * Verify the syrup shutoff valve at the solution module is turned on. * Confirm that any syrup shutoff valves at the back of the dispenser are not turned off. * Ensure the syrup supply pressure at the dispenser reads 70 PSIG (483 kPag), adjusting the regulator if necessary. * Check that the syrup pressure transducer is connected and working properly.
  • B
    Bradley DillonSep 5, 2025
    What does error #340: Flavor Add-On Board Missing mean on my FBD Beverage Dispenser and what should I do?
    • J
      Jenny BrownSep 5, 2025
      Error #340 'Flavor Add-On Board Missing' on your FBD Beverage Dispenser indicates that the dispenser cannot detect the flavor add-on board because the board is missing or damaged. To resolve this: * Ensure the software matches the dispenser’s hardware configuration. * Ensure the flavor add-on board is installed and seated properly on the control board. * Replace the flavor add-on board if faulty.
  • D
    Donald WillisSep 4, 2025
    What does error #1000: Gas #2 - Low Regulated N2 PSI mean on my FBD Beverage Dispenser and how to fix it?
    • M
      mrodriguezSep 4, 2025
      Error #1000 'Gas #2 - Low Regulated N2 PSI' on your FBD Beverage Dispenser means that the regulated N2 pressure dropped below 50 PSIG (345 kPag). To fix it: * Ensure the N2 supply is not low. * Check the 'Gas 2' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).
  • R
    Reginald WeaverSep 3, 2025
    What does error #460: Gas #1 - Low Regulated N2 PSI mean on my FBD Beverage Dispenser and how to fix it?
    • S
      susan84Sep 3, 2025
      Error #460 'Gas #1 - Low Regulated N2 PSI' on your FBD Beverage Dispenser means that the regulated N2 pressure dropped below 50 PSIG (345 kPag). To fix it: * Ensure the N2 supply is not low. * Check the 'Gas 1' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).
  • C
    Courtney LeeSep 2, 2025
    What does error #480: Gas #2 - Low Regulated CO2 PSI mean on my FBD Beverage Dispenser and how to fix it?
    • D
      Danny HaynesSep 2, 2025
      Error #480 'Gas #2 - Low Regulated CO2 PSI' on your FBD Beverage Dispenser means that the regulated CO2 pressure dropped below 50 PSIG (345 kPag). To fix it: * Ensure the CO2 supply is not low. * Check the 'Gas 2' regulator on the header tray and ensure it is set to 60 PSIG (414 kPag).