77X INSTALLATION & OPERATION MANUAL
771/772/773/774 MODELS
30
7.15 Wake/Sleep Schedule Menu
The wake/sleep feature (Figure 7.26) makes the dispenser wake up and go to sleep automatically. This feature is useful
for locations that are closed overnight. The wake and sleep times can be different for each day of the week or common for
all days.
7.16 Manual On/O Menu
The MANUAL ON/OFF menu (Figures 7.27 and 7.28) allows the service technician to turn on and off any solenoid, motor
or status light in the dispenser. This is useful when purging the barrels or troubleshooting the dispenser.
Note: For protection, all solenoids will automatically turn o after 6 minutes.
For multi-flavor dispensers, there is also a MULTI-FLAVOR ON/OFF menu (Figure 7.29) to turn on and o the flavor solenoids.
Figure 7.26
Figure 7.27 Non-DCC* Units Figure 7.28 DCC* Units
* DCC - Dynamic Charge Control
Figure 7.29