FLT
®
Series FlexSwitch
TM
APPENDIX C - APPROVAL INFORMATION
Fluid Components International LLC 85
Annex 1 to Certificate of Conformity IECEx DEK 14.0080X, issue 0
Annex 1 to IECEx TR NL/DEK/ExTR14.0088/00
Annex 1 to EU Type Examination Certificate KEMA 02ATEX2166 X, issue 4
Page 3 of 5
Model decoding FLT93L series In-line style
In-line version (thermowells placed inside pipe spoolpiece)
I.
ATEX approved
IECEx approved
B 316L stainless steel
III.
Process
temperature
2
-40 °C to + 260 °C (only with remote enclosure, pos. XII ≠ 0)
(Refer to thermal data in this Annex.)
IV.
custom Not relevant for Ex type of protection
V.
Material of
sensor
2
3
Hastelloy C276
Monel 400
VI.
custom
Process connection not relevant for Ex type of protection. Material of
flange stainless steel, carbon steel or same as sensor.
VII.
Local enclosure
(local = at
sensor)
C
D
Sensor with cable pigtail: requires Ex d adapter and cable gland (only
when I = 3 and XII = B, G, C)
Aluminium Ex d enclosure with single cable entry
Aluminium Ex d enclosure with dual cable entry
Stainless steel Ex d enclosure with single cable entry
VIII.
(type of
4
5
Standard version of electronics
Electronic with hermitically sealed relays contacts
IX till
XI
alarm point 1, 2,
custom Not relevant for Ex type of protection
XII.
Remote
enclosure
B
G
None (the electronics is mounted inside local enclosure of pos. VII.)
Aluminum Ex d enclosure with single cable entries
Aluminum Ex d enclosure with dual cable entries
Stainless steel Ex d enclosure with single cable entry
till
Cable material
& length
custom PVC or Teflon cable, length not relevant of Ex type of protection
Electrical data:
Power supply : 115 Vac (± 15) 50/60 Hz; 13 watts, 100 mA max.
: 230 Vac (± 10) 50/60 Hz; 14 watts, 50 mA max.
: 24 Vac (18 V to 26 Vac) 50/60 Hz; 7 watts, 230 mA max.
: 24 Vdc (21 V to 30 Vdc); 7 watts, 230 mA max.
Relay Rating : 115 Vac / 240 Vac or 24 Vdc, 6A
Sensing Element Heater Power : 3.0 W max.