Controller and Target cannot be enabled both because of mutual exclusion.
Module will soft reboot if profile selection changed
Example: Read current profile selection
<<
AT+PROFILE
>>
+PROFILE=1195
Example: Enable SPP, GATT Server, HFP Source, A2DP Source profile, disable the others
<<
AT+PROFILE=83
>>
OK
2.1.3. Read Firmware Version
Format: AT+VER
Response: +VER=Param
Param: Firmware version
Example: Read module’s firmware version
<<
AT+VER
>>
+VER=FSC-BT805B, V1.0.0,20160120
>>
OK
2.1.4. Read BR/EDR MAC Address
Format: AT+ADDR
Response: +ADDR=Param
Param: Module’s BR/EDR MAC address (12 Bytes ASCII)
Example: Read Module’s BR/EDR MAC address
<<
AT+ADDR
>>
+ADDR=DC0D30123456
>>
OK