EasyManua.ls Logo

Feasycom FSC-Blueware - Accept;Reject Remote Pairing Request; Read;Write Class of Device; Read;Clear Paired Record

Default Icon
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
Response: +SSP=Param
2.1.10. Accept/Reject Remote Pairing Request
Format: AT+CFM=Param1, Param2
Param1: 12 Bytes MAC address of remote device
Param2: 0/1
(0)
Reject remote pairing request
(1)
Accept remote pairing request
Description: Only used for pairing request in pairing mode 3, see AT+SSP
2.1.11. Read/Write Class of Device
Format: AT+COD{=Param}
Param: Class of device (6 bytes ASCII, default:240404 Handsfree device)
Response: +COD=Param
2.1.12. Read/Clear Paired Record
Format: AT+PLIST{=Param}
Param:(0/1~8/12 Bytes MAC address)
(0)
Clear all paired record
(1~8)
Clear specific paired record with index
(MAC)
Clear specific paired record with MAC address
Response1: +PLIST=Param1, Param2, Param3{, Param4}
Param1: (1~8) Paired device’s index
Param2: (MAC) Paired device’s MAC address
Param3: A base-10 representation of a bit field, support profiles of device, see AT+PROFILE
Param4: (UTF8) Paired device’s name
Response2: +PLIST=E: End of the paired record
Example: Read module’s paired record
<<
AT+PLIST

Table of Contents