Go to fetco.com for the latest versions of all information Page 6 User Guide & Operator instructions P194Re0 November 2020
B GENERAL B
ewer Operation Control Settin
s, Ad
ust Brew Flow Rate
POSITION Program Items Factory set Default Programming Range Increments Notes
B1 Tank Temp.
200°F -or- 93°C
NOTE: Units are in
En
lish b
default
170° to 207°F
77° to 97°C
1.0°F
0.5°C
Chart to correct for
high altitude below
B2 Brew at Temp. “YES” ON/OFF YES/NO SEE NOTE BELOW
B3
Units of Measure
TEMPERATURE
°F Fahrenheit Fahrenheit/Celsius C/F
NOTE: Overwrites
user settin
s
(see page 9)
B4
Units of Measure
VOLUME
L LITERS Gallons/Liters L/Gal
NOTE: Overwrites
user settings
(see page 9)
B5
Show Tank
Temperature
YES YES/NO
To display HW tank
temperature on screen
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
0 0 205 212.0 96 100.0
500 152 205
211.0 96
99.5
1000 305 200
210.1 93
98.9
2000 610 200
208.1 93
97.8
2500 762 200
207.2 93
97.3
3000 914 200
206.2 93
96.8
3500 1067 197 205.3 92 96.3
4000 1219 195 204.3 91 95.7
4500 1372 194 203.4 90 95.2
5000 1524 194 202.4 90 94.7
5500 1676 193 201.5 89 94.2
6000 1829 192 200.6 89 93.6
6500 1981 191 199.6 88 93.1
7000 2134 190 198.7 87 92.6
7500 2286 188 197.8 86 92.1
8000 2438 187 196.9 86 91.6
8500 2591 185 196.0 85 91.1
BREW AT TEMPERATURE DEFINITIONS
DEFAULT: BREW AT TEMP: “ON”
(FACTORY DEFAULT FOR BREWER)
“BREW at TEMP:
-Batch will not start if tank temperature
is below set point.
-Display will show “HEATING”
and hot water tank temperature
The “BREW START” entry buttons will not
illuminate until the hot water tank reaches the
selected temperature.
Controls allow both sides of dual brewer to
operate if one side has an ongoing brew
started and the second side brew is selected.
Notifications shown on screen:
TEXT: HEATINGTank above 87°C/189°F-
will allow brew at low temperature.
Coffee flavor may be affected
TEXT: L. HEATTank above 76°C/169°F-
will allow brew at low temperature.
Coffee flavor will be noticeably affected
Tank temp
STOP is not lit
BREW START
buttons not lit.
and are disabled
.
Buttons will
illuminate “READY”
when hot water tank
temperature is at
setpoint
Hot water tank not at
brew temp setpoint.
HEATING
160°F
USER SELECTABLE OPTION: BREW AT TEMP: OFF
(Not recommended) Unit will operate at cold temperature
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off
STOP