32
Parameter / Test condition
Min
Type
Max
Unit
Housing
Material
Glass-fibre-reinforced polyester
l
HxWxD
Dimension Height
10.236
260
in
mm
Width
8.976
228
in
mm
Depth
8.976
135
in
mm
m Weight
12.13
5.5
kg
CS
Term
Terminal connection capacity solid
stranded
12
4.0
14
2.5
AWG
mm
2
AWG
mm
2
F-Relay
DC- Type: DC60MP
V
Load
Load voltage range
5
60
V
DC
I
Load
Load current
3
A
DC
V
Dropout
Dropout voltage@I
LoadMax
1.5
V
DC
I
Leakage
Off state leakage current
1
mA
DC
AC- Type: MP240D4
V
Load
Load voltage range
24
240
V
AC
I
Load
Load current
4
A
AC
V
Dropout
Dropout voltage@I
LoadMax
1.6
V
AC
I
Leakage
Off state leakage current@f
Load
= 25 to 65 Hz
5
mA
AC
Ambient conditions
Enclosure type
4X
4
Protection against external mechanical im-
pacts
IK 09
5
T
A
6
Operating temperature range
(display does not operate below -4°F/-20°C)
-13
-25
104
40
°F
°C
T
STG
Storage temperature range
-13
-25
158
70
°F
°C

Related product manuals