11
ASSOCIATIONS
Notication report:
The device uses Notication Command Class to report dierent events
to 1st association group (Lifeline).
Notication Type Triggering Event
CO Alarm
1. Carbon monoxide detected, unknown location
2. Carbon monoxide test
3. Replacement required
Heat Alarm Overheat detected, unknown location
Home Security Tampering, product covering removed
Power Management Replace battery soon
System System hardware failure