Wake up interval
Available settings: 0 or 3600-43200 (in seconds, 1h - 12h)
Default setting: 21 600 (every 6 hours)
The CO Sensor will wake up at each dened time interval and always try
to connect with the main controller. After successful communication
attempt, the device will update conguration parameters, associations,
settings and then will go into Z-Wave communication standby.
After failed communication attempt (eg. no Z-Wave range) the device
will go into Z-Wave communication standby and retry to establish con-
nection with the main controller after the next time interval.
Setting wake up interval to 0 disables sending Wake Up notication to
the controller automatically. Wake up may be still performed manually
using the button.
Longer time interval means less frequent communication and thus a
longer battery life.
2. Z-Wave notications
This parameter allows to set the actions which result in sending noti-
cations to the Z-Wave network controller.
Available settings: 0 - both actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
3 - both actions enabled
Default setting: 0 Parameter size: 1 [byte]
3. LED diode indications
This parameter allows to set the actions which result in LED diode
indications. This parameter does not apply to the most important ac-
tions, such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
The CO Sensor allows to customize its operation to users needs. The
settings are available in the FIBARO interface as simple options that
may be chosen by selecting the appropriate box.
In order to congure the
CO Sensor
(using the Home Center controller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced” tab.
3. Modify values of chosen parameters.
4. Save the changes.
5. Press the button to wake up the device.
NOTE
Entering invalid value
of parameter will re-
sult in response with
Application Rejected
frame and not setting
the value.