SPECIFICATIONS
#10: Specications
Power supply:
Battery life:
Lifespan under typical
conditions:
CO concentration
measurement range:
Measuring accuracy:
Alarm response times on
default settings:
Alarm siren sound level:
Operating temperature:
Operating humidity:
Conformity with EU
requirements:
Radio protocol:
Radio frequency:
Range:
Dimensions (d x h):
CR123A 3.0V battery (included)
3 years on default settings
(tested with Panasonic Industrial Lithium)
8 years
0 - 450 ppm
±10ppm / ±5%
50ppm 60-90min
100ppm 10-40min
300ppm <1.5min
85 dBA at 3 meters (10 feet)
0 - 50°C
10-95%RH without condensation
RED 2014/53/EU
RoHS 2011/65/EU
EN 50291-1:2010
Z-Wave (500 series chip)
868.4, 868.42 or 869.8 MHz EU;
908.4, 908.42 or 916.0 MHz US;
921.4, 921.42 or 919.8 MHz ANZ;
869.0 or 869.02 MHz RU;
up to 50m outdoors
up to 40m indoors
(depending on terrain
and building structure)
65 x 28 mm
CAUTION
Using batteries other
than specied may
result in explosion.
Dispose of properly,
observing environ-
mental protection
rules.
!
NOTE
Radio frequency of
individual device
must be same as your
Z-Wave controller.
Check information
on the box or consult
your dealer if you are
not sure.
i
NOTE
Replace the device be-
fore date on the front
or if sensor error is de-
tected.