ADVANCED PARAMETERS
19. Value of BASIC OFF command sent to 4th association group
This parameter denes the value of BASIC OFF command sent to devices in
4th association group after falling below the CO level set in parameter 17.
Available settings: 0-99 or 255
Default setting: 0 (turn o) Parameter size: 2 [bytes]
20. Temperature reporting time interval
Time interval (in seconds) between consecutive reports of temperature
(done by built-in temperature sensor). Short time interval means more
frequent communication, which results in shortened battery life.
Available settings: 0 - no periodical reports
10-1440 (5min - 12h, in 30s steps)
Default setting: 0 Parameter size: 2 [bytes]
21. Temperature reporting hysteresis
This parameter denes a minimum change in temperature resulting
in a report being sent to the main Z-Wave controller.
Available settings: 1-20 (0.5°C - 10°C, each 0.5°C)
Default setting: 2 (1°C) Parameter size: 1 [byte]
22. Threshold of exceeding the temperature
This parameter denes the temperature level, which exceeding will
result in sending actions set in parameters 2, 3 and 4.
Available settings: 1-85 (1°C - 85°C, each 1°C)
Default setting: 55 (55°C) Parameter size: 1 [byte]
23. CO meter activation
This parameter activates reporting the value of CO concentration lev-
el to the main Z-Wave controller.
Available settings: 0 - disabled
1 - enabled
Default setting: 1 (enabled) Parameter size: 1 [byte]
25. CO level reporting hysteresis
This parameter denes a minimum change in CO concentration level
which results in sending a new value to the main Z-Wave controller.
Available settings: 2-6 (10 ppm - 30 ppm, each 5 ppm)
Default setting: 2 (10 ppm) Parameter size: 1 [byte]
26. Threshold of CO meter activation
This parameter denes the CO concentration level, which exceeding will
result in sending a new value to the main Z-Wave controller, according
to parameter 25 settings. Adjusting the value allows to get the accurate
data in case of danger and helps to save the battery in normal conditions.
Available settings: 10-255 (ppm)
Default setting: 30 (30 ppm) Parameter size: 2 [bytes]
NOTE
Setting parameter 19
to appropriate value
will result in:
0 - turning associated
devices o
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on.
i
NOTE
Values received by
the controller may be
used for graphs of CO
concentration level.
i
NOTE
Parameter 25 is close-
ly related to parame-
ter 26.