14
ADVANCED PARAMETERS
12. Value of BASIC OFF command sent to 2nd association group
This parameter denes the value of BASIC OFF command sent to de-
vices in 2nd association group after the CO Alarm cancellation.
Available settings: 0-99 or 255
Default setting: 0 (turn o) Parameter size: 2 [bytes]
13. Commands sent to 4th association group (CO Level)
This parameter denes commands sent to devices associated in 4th
association group (CO Level). Values of specied commands may be
set in parameters 16 and 19.
Available settings: 1 - BASIC ON
2 - BASIC OFF
3 - BASIC ON & BASIC OFF
Default setting: 3 (ON & OFF) Parameter size: 1 [byte]
14. CO level required for sending BASIC ON command to 4th as-
sociation group
This parameter denes the minimum level of CO concentration which
exceeding will result in starting the timer set in parameter 15.
Available settings: 25-400 - CO concentration level in ppm
Default setting: 40 (40 ppm) Parameter size: 2 [bytes]
15. Time required for sending BASIC ON command to 4th associ-
ation group
This parameter denes the time during which the level of CO concen-
tration should remain above the value set in parameter 14 to send the
BASIC ON command to 4th association group.
Available settings: 0 - immediate sending of BASIC ON command
1-2880 (30s - 24h, in 30s steps)
Default setting: 0 Parameter size: 2 [bytes]
16. Value of BASIC ON command sent to 4th association group
This parameter denes the value of BASIC ON command sent to de-
vices in 4th association group after exceeding the CO level set in pa-
rameter 14 through the time set in parameter 15.
Available settings: 0-99 or 255
Default setting: 255 (turn on) Parameter size: 2 [bytes]
17. CO Level required for sending BASIC OFF command to 4th as-
sociation group
This parameter denes the level of CO concentration below which
falling will result in sending the BASIC OFF command to 4th associa-
tion group.
Available settings: 10-400 - CO concentration level in ppm
Default setting: 25 (25 ppm) Parameter size: 2 [bytes]
NOTE
Setting parameters
11-12 to appropriate
value will result in:
0 - turning associated
devices o
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on
i
NOTE
Parameter 14 value
must be at least 4 ppm
higher than parame-
ter 17 value.
i
NOTE
Setting parameter 16
to appropriate value
will result in:
0 - turning associated
devices o
1-99 - forcing level of
associated devices
255 - setting associat-
ed devices to the last
remembered state or
turning them on.
i
NOTE
Parameter 17 value
must be at least 4 ppm
lower than parameter
14 value.
i