ADVANCED PARAMETERS
Available settings: 0 - all actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
4 - lack of Z-Wave range
Default setting: 0 Parameter size: 1 [byte]
4. Acoustic signals
This parameter allows to set the actions which result in acoustic sig-
nals. This parameter does not apply to the most important actions,
such as CO Alarm, Malfunction Alarm and Low Battery Alarm.
Available settings: 0 - all actions disabled
1 - tampering (opened casing)
2 - exceeding the temperature
4 - lack of Z-Wave range
Default setting: 0 Parameter size: 1 [byte]
7. Associations in Z-Wave network security mode
Parameter denes how commands are sent in specied association
groups: as secure or non-secure. Parameter is active only in Z-Wave net-
work security mode. It does not apply to 1st “Lifeline” association group.
Available settings: 1 - 2nd group sent as secure
2 - 3rd group sent as secure
4 - 4th group sent as secure
8 - 5th group sent as secure
16 - 6th group sent as secure
32 - 7th group sent as secure
Default setting: 63 Parameter size: 1 [byte]
10. Commands sent to 2nd association group (CO Alarm)
This parameter denes commands sent to devices associated in 2nd
association group (CO Alarm). Values of specied commands may be
set in parameters 11 and 12.
Available settings: 1 - BASIC ON
2 - BASIC OFF
3 - BASIC ON & BASIC OFF
Default setting: 3 (ON & OFF) Parameter size: 1 [byte]
11. Value of BASIC ON command sent to 2nd association group
This parameter denes the value of BASIC ON command sent to de-
vices in 2nd association group after the CO Alarm activation.
Available settings: 0-99 or 255
Default setting: 255 (turn on) Parameter size: 2 [bytes]
NOTE
Parameter 3 values
may be combined, e.g.
1+2+4=7 means that
all actions will be ac-
tive.