SAFETY FEATURES
A safety switch is located on the printed circuit board on the right side under the chair. If something
(e.g. a foot) come in between the lifting mechanism and the base of the chair when the chair is in
motion, this safety switch will immediately stop all movements. The chair can be restarted as soon
as whatever caused the stop has been removed. For improved safety the foot control also works as
an emergency stop switch. Hit any of the control switches of the foot control when the chair is in
motion and all movements of the chair stops immediately.
Activate any button for emergency stop
CONTROLLING THE CHAIR
F NOTE! If some other device is disturbing wireless remote control transmission, immediately
start using remote controls with recharge cable.
FOOT CONTROL
All movements of the F1 chair are controlled by means of the cordless foot control. The foot
control contains all functions for the manual operation of the chair. It can be used also for
controlling F1 unit options. In addition, the foot control is used for programming and activating
different pre-set working positions. Transmission of the electro-magnetic signals between the foot
control and the chair is accomplished by means of inductive fields. In cases when you have more
than one F1 chair in your office the foot controls have different codes in order to prevent any
interference.
The foot control is operated by rechargeable accus size AA. To charge the accus just connect the
foot control to the cord that is provided with the chair. In the event of malfunction in the cordless
transmission, connect the cord used for charging the accus to the foot control. This will override
the cordless transmission, and the chair can now be operated as usual. Do not use normal
batteries instead of accus in the foot control!
F Hint: If accus have exhausted, the chair can be operated as normally with recharge cable.
Safety switch. Activated
when rear is lift upwards.
3
2
Lever
1
Batteries