FireClass FC500 - Navigating the Main Window; File Menu Operations; Creating New Installations; Opening Saved Installations

FireClass FC500
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Main window
From the FireClass FC500 (FC501_FC503_FC506)
Console main screen, click File and then New, to display
the window shown in Figure 2 where you select the
firmware release of the control panel to program. Click the
green tick to accept the selection. The following selections
describe the File, Tools and Help menus.
Table 1: Icons on the Main window
Icon
Description
Click this icon, in the Master control panel, and
the window in Figure 3.2 appears. In this
window, a client panel can be inserted.
Notes:
The FC501 panel neither has any client
panel, nor can it be added as a client
panel of the FC503 or FC506 panel.
FC503 can have FC506 as a client
panel and vice versa.
Click this icon to remove the selected Client
control panel.
Opens the window Panel details where you
check or insert various programming. See Figure
5.
Checks Panel details. Enter the name and
address of the control panel or customer. See
Figure 5.
Downloads the programming via serial link or
USB or TCP/IP to the connected control panel
after entering correct installer password.
Uploads the programming of the connected
control panel after entering correct installer
password.
Selects the loop for inserting devices.
Start operations in real time. This feature allows
you to view the status of the FC501, FC503 and
FC506 control panel in real time on a computer
using the FC500IP module connected to the
network, or by using the serial port or USB port.
File menu
The File menu allows you to manage customer account
data. The following are the various selections within the
File menu.
New
Click New to create a new installation and assign the
factory default values to all programming parameters.
Open
Click Open to retrieve a previously saved customer
installation file. Locate the required installation file and
double click to open it.
Note: You can have more than one installation file open at
the same time. Pay attention to the tabs on the left side to
ensure you are editing the correct file.
Save
Click Save to save the changes in the current installation,
if you modified the installation data.
Save as
Click Save as if you created a new installation or want to
save an existing installation under a new name.
Close
Click Close to close the current installation. You will be
prompted to save any changes made.
Exit
Click Exit to close the FireClass FC500
(FC501_FC503_FC506) Console. You will be prompted to
save any changes made.
1
RS-232 Female connector, solder side
2
4 way MTA connector
3
Fire panel board