Connecting Electrical Loads
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
on position.
3.Plug in and turn on the desired 120 or 240 Volt
AC, single phase, 60Hz electrical loads. It is
better to attach the item with largest load first.
Stopping the Engine
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated
via the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
When applying a load, do not exceed the maximum
wattage rating of the generator when using one or
more receptacles. Also, do not exceed the amperage
rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
Let the generator run at no-load for two
minutes to stabilize internal temperatures
of the engine and generator.
English Customer Service: 1-844-FIRMAN1
NOTICE
CO Alert automatically shuts down the engine
when harmful levels of carbon monoxide
accumulate around the generator or a CO Alert
fault occurs. After shutdown, the CO Alert
indicator light will blink for at least five minutes
per the chart below.
Color
Description
Red
Yellow
CO Alert fault occured*.
See FIRMAN authorized service dealer.
* Yellow light will blink for five seconds at the
startup of generator to show CO ALERT is
functioning properly.
TM
Carbon monoxide accumulated
around generator. Prior to restart
move generator to an open, outdoor
area 20 ft. (6 m) from occupied
spaces with exhaust pointed away.
Air out premises (open windows
and doors) before reoccupying
property. Automatic shutoff is an
indication generator was improperly
located.
If you start to feel sick, dizzy, weak,
or your homes carbon monoxide
alarm sounds while using this
product, get to fresh air right away.
Call emergency services. You may
have carbon monoxide poisoning.
•• ••
••
CO Alert
Carbon Monoxide (CO) Shutdown System
CO Alert DOES NOT replace carbon monoxide
alarms.
Install battery-powered carbon monoxide
alarm(s) in your home. Dont run generator in
enclosed areas.