2.4.3 Starting up the generator
WARNING: Automatic start-upDeadly danger! - The generator can be equipped with an
Autostart function. This means that the generator is
started by an external signal. In order to prevent an
inadvertent start-up, the starter battery must be
disconnected before work on the generator may
commence.
Fig. 2.4.3-1: Switch on the panel1. Switch on the xControl CP-G
The remote control panel is started by pressing the On/Off
button. The On/Off button must be pressed until the Home
page is displayed.
Fig. 2.4.3-2: Start the generator.2. Press the Start/Stop - Enter key
Fig. 2.4.3-3: Self-test3. The xControl performs a self-test.
Fig. 2.4.3-4: Preheating4. The xControl preheats the diesel engine.
After preheating, the generator is started by the xControl
system.
Fig. 2.4.3-5: Electric starter5. Starter on.
In order to minimise current consumption, preheating is
interrupted briefly when the starter is operated.