35
10.0 FAULT MODE
10.1 BINARY CODE
The Fault Codes are displayed using a BINARY NUMBERING SYSTEM. By using this system
each unique fault code can be given a number. Each fault code is listed under this number in the
FAULT CODE DESCRIPTIONS Section.
Each LED represents a certain number (see above). If the LED is ON the number it represents can
be added together with the number from other LED’s that are also ON.
EXAMPLES USING THE DATA DISPLAYS
1. Press the SPIN SPEED UP button until the HOLD and SLOW SPIN LED’s turn on. The
WASH PROGRESS LED’s are displaying the FAULT CODE at last fault.
Indicates the LED is ON
Ο Indicates the LED is OFF
This pattern of LED’s can also be written as 00110 001. The 1 = LED ON, 0 = LED OFF.
This is Binary Count 32 + 16 + 1 = 49. Fault Code #49 is a COLD WATER VALVE FAULT.
2. Use the ADVANCE button to switch between Data Displays and Switch Test mode.
OR
3. Return to normal operation by pressing the POWER button.