12.2 MECHANICAL DISASSEMBLY PROCEDURE
1. Isolate from the power supply.
2. To remove the lid, open it to the upright position and lift it clear.
3. Remove the 2 screws from the rear of the console. Raise the console for access to the Motor
Controller Module, Display Module, Inlet Chamber, Water Valves and associated wiring.
An anti-static wrist strap must be used when handling electronic Modules and the Rotor Position
Sensor. Clip the strap to a ground connection.
When removing the cover, the
rear clips must be released from
the back of the cabinet and the
cover lifted upwards first.
4. Disconnect the pressure tube from the pressure sensor.