Type EZR
4
TYPE
OUTLET PRESSURE OR
SEnSE PRESSURE
(1)
(ExHAUST) PRESSURE
(cOnTROL) PRESSURE
161AY 150 (10,3) 150 (10,3) 150 (10,3)
- - - - - - - -
161EB 1500 (103) 1200 (82,7) 750 (51,7)
161AYM 150 (10,3) 150 (10,3)
- - - -
150 (10,3) 150 (10,3)
161EBM 1500 (103) 1200 (82,7) 1500 (103) 750 (51,7)
PRX Series 1480 (102) 1480 (102) 1480 (102) 1480 (102) 1480 (102)
1. Maximum pressure to prevent the casings from bursting during abnormal operation (leaking to atmosphere and internal parts damage may occur).
Table 3. Pilot Pressure Ratings
As the outlet pressure rises toward the outlet pressure
setting, it compresses the pilot diaphragm against the
pilot control spring and allows the pilot valve plug or
disk close. Loading pressure begins building on the
Type EZR diaphragm and plug assembly. The loading
pressure, along with force from the main spring,
pushes the diaphragm and plug assembly onto the
tapered-edged seat, producing tight shutoff.
—Low-pressure pilot with an outlet
pressure range of 6-inches w.c. to 7 psig
(15 mbar to 0,48 bar). Pilot bleeds (exhausts)
downstream through the sense (control) line.
Table 2. Outlet (Control) Pressure Ranges, Proportional Bands, and Pilot Control Spring Information
—The monitor version of the Type 161AY
pilot. The pilot bleed (exhaust) is isolated from the sense
(control) line. This pilot is used in monitoring systems
requiring an isolated pilot bleed (exhaust).
—High accuracy pilot with an outlet
pressure range of 5 to 350 psig (0,34 to 24,1 bar).
Pilot bleeds (exhausts) downstream through the sense
(control) line.
—The monitor version of the Type 161EB
pilot. The pilot bleed (exhaust) is isolated from the sense
(control) line. This pilot is used in monitoring systems
requiring an isolated pilot bleed (exhaust).
—Outlet pressure range of 14.5 to
435 psig (1,00 to 30,0 bar). The Type PRX/120 can be
TYPE
OUTLET (cOnTROL)
PRESSURE RAnGE
(1)
161AY or
161AYM
6 to 15-inches w.c.
0.5 to 1.2 psig
1.2 to 2.5 psig
2.5 to 4.5 psig
4.5 to 7 psig
(15 to 37 mbar)
(34 to 83 mbar)
(83 mbar to 0,17 bar)
(0,17 to 0,31 bar)
(0,31 to 0,48 bar)
1-inch w.c.
1-inch w.c.
0.5 psig
0.5 psig
0.5 psig
(3 mbar)
(2)
(3 mbar)
(2)
(34 mbar)
(2)
(34 mbar)
(2)
(34 mbar)
(2)
1B653927022
1B537027052
1B537127022
1B537227022
1B537327052
Olive drab
Yellow
Light green
Light blue
Black
0.105
0.114
0.156
0.187
0.218
(2,67)
(2,90)
(3,96)
(4,75)
(5,54)
3.75
4.31
4.13
3.94
4.13
(95,2)
(109)
(105)
(100)
(105)
161EB or
161EBM
5 to 15 psig
10 to 40 psig
30 to 75 psig
70 to 140 psig
130 to 200 psig
200 to 350 psig
(0,35 to 1,0 bar)
(0,69 to 2,8 bar)
(2,1 to 5,2 bar)
(4,8 to 9,7 bar)
(9,0 to 13,8 bar)
(13,8 to 24,1 bar)
0.5 psig
0.5 psig
0.6 psig
1.3 psig
1.5 psig
3 psig
(34 mbar)
(2)
(34 mbar)
(2)
(41 mbar)
(2)
(90 mbar)
(2)
(0,10 bar)
(2)
(0,21 bar)
(2)
17B1260X012
17B1262X012
17B1259X012
17B1261X012
17B1263X012
17B1264X012
White
Yellow
Black
Green
Blue
Red
0.120
0.148
0.187
0.225
0.262
0.294
(3,05)
(3,76)
(4,75)
(5,71)
(6,65)
(7,47)
3.75
3.75
4.00
3.70
3.85
4.22
(95,2)
(95,2)
(102)
(94,0)
(97,8)
(107)
161EB
(4)
30 to 300 psig (2,1 to 20,7 bar) 6 psig (0,41 bar) 15A9258X012 Green 0.243 (6,17) 1.88 (47,7)
TYPE
OUTLET (cOnTROL)
PRESSURE RAnGE
AccURAcY cLASS (Ac)
(1)
PRX/120
PRX/125
14.5 to 26 psig
23 to 44 psig
41 to 80 psig
73 to 123 psig
(1,00 to 1,8 bar)
(1,6 to 3,0 bar)
(2,8 to 5,5 bar)
(5,0 to 8,5 bar)
2.5%
2.5%
2.5%
2.5%
GD25524X012
GD25523X012
GD25518X012
GD25522X012
Yellow
Green
Blue
Black
0.110
0.126
0.138
0.157
(2,79)
(3,20)
(3,50)
(3,99)
2.16 (54,9)
116 to 210 psig
203 to 334 psig
319 to 435 psig
(8,0 to 14,5 bar)
(14,0 to 23,0 bar)
(22,0 to 30,0 bar)
1%
1%
1%
GD25521X012
GD25520X012
GD25586X012
Silver
Gold
Aluminum
0.177
0.197
0.236
(4,50)
(5,00)
(5,99)
2.16
2.00
2.00
(54,9)
(50,8)
(50,8)
PRX/120-AP
PRX/125-AP
435 to 1000 psig (30,0 to 69,0 bar) 1% GD27379X012 Clear 0.335 (8,51) 3.93 (99,8)
1. Proportional band and Accuracy Class include outlet pressure drop plus hysteresis (friction), but do not include lockup.
2. Proportional band was determined with a pressure drop ranging from 50 to 150 psig (3,5 to 10,3 bar). Approximately double the proportional band if the pressure drop is less
than 50 psig (3,5 bar).
3. With Type 112 restrictor set on 2. With Type PRX restrictor turn the restrictor screw one turn counterclockwise from fully seated.
4. Should only be used as the intermediate reduction pilot on the Type EZR worker/monitor systems.