SECTION 1
INFORMATION AND REQUIREMENTS
1.0 APPLIANCE INFORMATION
Main injector : (1 off) Bray Injector Elbow size 360
Pilot Type : S.I.T.140 Series NG size 27
Max. Gross Heat Input : 5.25 kW
Min. Gross Heat Input : 2.05 kW
Gas Rate : 0.470 m
3
/hr (High)
0.190 m
3
/hr (Low)
Cold Pressure : 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition : Integral to gas valve
Electrode Spark Gap : 4.0mm
Weight (Product & Fender) : 33 kg
Weight (Canopy) : 23 kg
3
673mm
445mm
290mm
198mm
716mm
645mm
Fig 1 -