57 of 59 GH-24, GH-30, GH-45, GH-60 Rev.003
TROUBLESHOOTING
The motor has stopped completely
o Check to see if there is power to the unit
o Check the emergency switch position
o Check the inverter inside of the electrical cabinet for an error code. If there is an error contact
Factory Service at 800-837-2503 to talk to a service technician.
o Check the fuses in the electrical cabinet
o Check the oil level in the power pack using the sight gage on the front
o Check for loose hydraulic connections or loose wiring
o Check that the motor relay hasn’t kicked out
The balls in the tap holder keep breaking
o Verify that there is no obstruction in the minimum clearance area that is restricting the downward
path of the tap holder.
o Verify that the chuck isn't striking the table or another work surface before, during, or after the
tapping process.
o Check for excessive shavings, grinding dust, etc., that could be getting into the chuck collar and
causing premature wear.
NOTE: The unit has a Limited Warranty on parts and labor. This warranty is void if changes to the unit or
attempts to repair it or its components are made without the express authorization of FlexArm Inc. Quick
change tap holders are considered perishable items and are not covered by the limited, three year
warranty on the FlexArm Tapping Machine.