14 of 59 GH-24, GH-30, GH-45, GH-60 Rev.003
SHUT DOWN PROCEDURE
1. Press the red stop button on the HMI to simply turn the motor off if it doesn’t need to be used for a
short period of time.
a. If the unit is left on for a short period of time without being used it will enter sleep mode and
turn off by itself.
2. The master switch only needs to be switched off if the unit will not be used for a longer period of time.
a. Before turning off the master switch press the red stop button on the HMI and allow the motor
in the power pack to completely spool down.
IMPROPER SHUTDOWN
Turning the machine off with the master switch before turning off the machine with the red button.
Turning the master switch off before the motor in the power pack has spooled down completely.
(approximately 3 seconds)
Suddenly removing power from the machine i.e. pulling the plug out of the wall before turning off the
machine with the red button.
Unplugging the unit before the motor in the power pack has spooled down completely. (approximately
3 seconds)
Pressing the green button while master switch is off and residual power is still in the inverter
(approximately 45 seconds after shutdown)
IF IMPROPER SHUTDOWN OCCURS
1. Reset the power pack by turning the master switch off.
2. Unplug the machine (wait 45 seconds to allow the inverter to reboot)
3. Plug the machine back in
4. Re-follow the steps in the startup procedure.