14 Settings FLUXUS F70x
UMFLUXUS_F7V4-6-2EN, 2017-10-01 131
14.2.7 Error Value Delay
The error value delay is the time after which an error value will be sent to an output if no valid measured values are avail-
able.
14.2.8 Alarm State Indication
14.2.9 Units of Measurement
It is possible to set the units of measurement for the length, temperature, pressure, density, kinematic viscosity, and sound
speed:
14.2.10 Setting for the Medium Pressure
It is possible to set whether the absolute or the relative pressure will be used:
Select edit to enter an error value delay. Select damping if the damping factor is to be
used as the error value delay.
For further information on the behavior of missing measured values see section 18.1.2 and
18.2.
Select on to display the alarm state during the measurement.
Fur further information on the alarm outputs see section 18.6.
Select mm or inch as the unit of measurement for the length. Press ENTER.
Select °C or °F as the unit of measurement for the temperature. Press ENTER.
Select bar or psi as the unit of measurement for the pressure. Press ENTER.
Select yes if lb/ft3 is to be used as the unit of measurement for the density.
Press ENTER.
Select g/cm3 or kg/m3 as the unit of measurement for the density. Press ENTER.
This display will only be indicated if lb/ft3 has not been selected as the unit of measure-
ment for the density.
Select mm2/s or cSt as the unit of measurement for the kinematic viscosity. Press ENTER.
Select m/s or fps as the unit of measurement for the sound speed. Press ENTER.
Select on or off. Press ENTER.
If on has been selected, the absolute pressure p
a
will be displayed/input/output.
If off has been selected, the relative pressure p
g
will be displayed/input/output.
p
g
= p
a
- 1.01 bar
The pressure and its unit of measurement will, e.g., be displayed in the program branch
Parameter. It will be followed by the selected pressure, indicated in parentheses.
a - absolute pressure
g - relative pressure
Note! All changes will be stored at the end of the dialog.
Error-val. delay
damping >EDIT<
SHOW RELAIS STAT
off >ON<
Length unit
>[mm]< [inch]
Temperature
>[°C]< [°F]
Pressure
>[bar]< [psi]
Density [lb/ft3]
no >YES<
Density unit
g/cm3 >kg/m3<
Viscosity unit
mm2/s >cSt<
Soundspeed unit
>[m/s]< [fps]
Pressure absolut
off >ON<
Fluid pressure
1.00 bar(a)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F706**-A2 Series and is the answer not in the manual?

Flexim FLUXUS F706**-A2 Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F706**-A2 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals