Flexim PIOX S705 User Manual

Default Icon
87 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SU_ModbusV2-8, 2015-03-02
SU_ModbusV2-8
Ergänzung zur Bedienungsanleitung - DEUTSCH
Modbus-Server
Supplement to User Manual - ENGLISH
Modbus Server
FLUXUS ADM 5x07 (Sonderausführung)
FLUXUS ADM 7x07, G70x, F705
FLUXUS ADM 8x27, F808, G80x
FLUXUS ADM 8x27P, G80xP
(mit passivem Stromausgang)
PIOX TS37x
PIOX S705

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Flexim PIOX S705 and is the answer not in the manual?

Flexim PIOX S705 Specifications

General IconGeneral
Measuring Range0.01 to 25 m/s
Accuracy±0.5% of reading ±0.01 m/s
Temperature Range-40 to +200 °C
Power Supply24 VDC or 100-240 VAC
Number of Channels1 or 2
Protection ClassIP66
Measurement PrincipleUltrasonic
TechnologyClamp-on
Output Signal4-20 mA, pulse, relay
Fluid CompatibilityLiquids and gases
EnclosureIP66
CommunicationEthernet
Repeatability0.15% of reading

Summary

2 Settings in the Transmitter

Input of the HotCode

Procedure for entering the HotCode to configure the transmitter.

Selection of the Mode

Options for transmitter operation via RS485 interface (sender or Modbus slave).

Input of the Transmission Parameters

Configuring baud rate, parity, and stop bits for Modbus communication.

4 Modbus Register Addresses of Selected Physical Quantities

5 Modbus Register Address Ranges of the Measurement Data

6 Request of a Physical Quantity or a Diagnostic Value

Start Address

Assignment of start addresses to different measuring channels for data retrieval.

Offset of the Physical Quantity or Diagnostic Value

Offsets used to calculate Modbus register addresses for physical quantities.

Offset of the Parameter

Offsets for parameters like state, unit, and time used in Modbus register addressing.

7 Request of Multiple Measured Values or Diagnostic Values

Request of Multiple Measured Values

Procedure for requesting multiple scaled measured values from a channel.

Request of the State of Multiple Measured Values

Procedure for requesting the state of multiple measured values from a channel.

Request of Multiple Diagnostic Values

Procedure for requesting multiple diagnostic values from a channel.

Request of the State of Multiple Diagnostic Values

Procedure for requesting the state of multiple diagnostic values from a channel.

B CRT Editor

Related product manuals