8.10 Adjusting an image manually
General
If you want to analyze an object with many different temperatures, you can use the
colors of the scale on different parts of the object.
In the left image below a correct analysis of the left cable is difficult to make if you
only auto-adjust the image. You can analyze the left cable more in detail if you increase
or decrease
the maximum temperature level;
the minimum temperature level;
the maximum and minimum temperature level at the same time.
Figure
This figure shows two infrared images of cable connection points.
In the image to the left, the image is auto-adjusted. In the right image the maximum
and minimum temperature levels have been changed to temperature levels near the
object. In the temperature scale to the right of each image you can see how the
temperature levels were changed.
10577503;a1
SEE ALSO
For procedures about how to adjust the image manually, see these sections:
Section 8.10.1 Increasing or decreasing the maximum temperature level on
page 38
Section 8.10.2 Increasing or decreasing the minimum temperature level on
page 39
Section 8.10.3 Changing both the maximum and minimum temperature level at
the same time on page 40
8
Publ. No. 1558299 Rev. a200 ENGLISH (EN) February 12, 2007 37
8 Operating the camera

Table of Contents

Other manuals for FLIR BCam

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR BCam and is the answer not in the manual?

FLIR BCam Specifications

General IconGeneral
BrandFLIR
ModelBCam
CategoryThermal cameras
LanguageEnglish

Related product manuals