10 Technical data
Disclaimer
FLIR Systems reserves the right to discontinue models, parts or accessories, and
other items, or change specifications at any time without prior notice.
Imaging
performance
Spectral range 7.5–13 μm
Focal Plane Array (FPA), uncooled microbolometer
120 × 120 pixels
Detector type
9 HzImage frequency
± 2.0°C (± 3.6°F) or ± 2% of readingAccuracy
■
InfraCAM: 0.20℃ (0.36℉)
■
InfraCAM SD: 0.12℃ (0.22℉)
Thermal sensitivity
Image
presentation
Screen 89 mm (3.5 in.) color LCD, 18-bit colors
Detector image interpolated to 240 × 240 pixelsInterpolation
Object
temperature
ranges
Object temperature
ranges
−10 to +350°C (+14 to +662°F)
Laser pointer
Classification Class 2
Semiconductor AlGaInP diode laser, 1 mW, 635 nm
(red)
Type
10