M500 Web Browser Interface
432-0012-01-12 Version 110 36
Azimuth and Elevation Offsets
After the camera is installed, the azimuth may be set to account for variations required during
installation. The azimuth direction should be directly toward the front of the vessel; the Elevation
Offset should be zero. The azimuth/elevation offset can also be set using the OSD menu.
Setting Park Position
The default park position is defined as 0° azimuth and -90° elevation. If a different park position is
desired, adjust the Park position as follows:
1. On the Maintenance->Sensor->Devices->Pan & Tilt page, enter the new values for Park
Position.
Scroll down
Azimuth Offset
to Save
to front of vessel
Elevation Offset
from horizontal
Stop and start
the server
Enter new
Scroll down
to Save
park position
Stop and start
the server