EasyManua.ls Logo

FLIR M500 - M500 Riser Installation Document

FLIR M500
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M500 Installation Guide
432-0012-01-12, version 110
August 2020
55
Appendix 1
Appendix 1
12.75
323.9
Top Down Riser OD
6X
.32
8.2
Riser Clearance Holes
Recommend:
M8 socket head cap screws, or
5/16" - 18 socket head cap screws, or
5/16" - 18 hex head sheet metal screws
Type and length dependant on mounting surface
316 stainless steel
Apply thread locker (Loctite 262 or equivalent)
4.79
121.6 Riser cable clearance hole
Recommended deck port:
30.0 [1.18] min
130.0 [5.12] max
NOT TO SCALE
11.75
298.5
Top down riser bolt circle
7.09
180.0
Base cup hole circle
M500 Riser Installation Document Sheet 1

Other manuals for FLIR M500

Related product manuals