8. Safety
Handle the meter carefully and do not subject the sensor to shock or excessive
vibration.
Keep the instrument dry.
Pack the battery separately when the meter is to be stored for periods longer than 60
days.
Do not use this device for purposes other than those described in this manual.
8.1 FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
WARNING
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
9. Specifications
Measurement range Moisture, 0 to 100
Measurement accuracy Relative measurements only
Measurement type Capacitance ball sensor (non-invasive)
Measurement detection depth Sensing depth for most common building materials
up to 4.0” (100mm), this may vary depending upon
material under test.
Response time 0.5 seconds
Display Backlit, multifunction LCD
Worklight High intensity white LED
Auto Power OFF (APO) After 30 minutes
Power supply 9V battery (rear compartment)