FLIRTA72_TA74USERMANUALDocumentIdentifier:TA72_TA74en‐US_AC
14
7. Specifications
7.1Generalspecifications
ClampJaw Flexibletypewithlockingmechanism
Coildiameter 0.3”(7.5mm);Coiltip(item3inFig.4‐1):0.5”(13mm)
Bendradius 1.5”(38mm)forTA72and3.1”(80mm)forTA74
FlexibleConductorlength 10”(25.4cm)forTA72and18”(45.7cm)forTA74
Worklights TwoWhiteLEDs
ACbandwidth 45to500Hz(sinewave)
Measurementrate 1.5samplespersecond,nominal
OperatingTemperature 32~122F(0~50C)
OperatingHumidity Max80%upto95°F(35°C)decreasinglinearlyto60%at113°F
(45°C)
StorageTemperature‐4~140F(‐20~60C)withoutbatteries
StorageHumidity 80%RHmaximum
TemperatureCoefficient 0.2xspecifiedaccuracy/C,<64.5F(18C),>82.4F(28C)
Altitude Maximumoperatingaltitude6562’(2000m)
Battery Two“AAA”1.5Vbatteries
Batterylife 160hourswithalkalinebatteries
AutoPowerOFF(APO) After10minutesofinactivity
withdisable
Dimensions(WxHxD) TA72:4.7x11.0x1.0”(120x280x25mm)
TA74:5.1x13.8x1.0”(130x350x25mm)
Weight TA72:6.0oz.(170g)withbatteries
TA74:7.1oz.(200g)withbatteries
Droptest 9.8ft.(3m)
AgencyApprovals UL,CE,RCM,andKC
SafetyStandards IP54
Forindooruseandinaccordancewiththerequirementsfordouble
insulationtoEN61010‐1,EN61010‐2‐032,EN61326‐1;CATIV600V,
CATIII1000V,PollutionDegree2