CoRe+
TM
Installation Guide
9
Wall or Post Mounting
Power Cable Entry from the Back
• Remove the plate to avoid the splatter of
particles in the equipment.
• Punch a hole of the appropriate diameter
to install the cable connector.
• Put the plate back in its place.
• Install the cable connector to
the punched hole, then the
cable. Make sure the
conductors are long enough
to reach the terminal block.
• Connect two
power conductors
(L1 and L2) and the
ground conductor
(GND)
• The grounding
conductor shall be
provided with
green or green and
yellow insulation.
L1 L2
• IMPORTANT, never
remove the
protection plate of
the keyhole.
•
•
Attach the head base to
the wall or the post with
appropriate type of
anchors.
Hang the head base to an
anchor (previously fixed to
the wall or post) via the
keyhole at the top. NEVER
REMOVE THE PROTECTION
PLATE
• Complete the mounting
of the head base by
installing an anchor
through the bottom hole.