Read and follow this operating manual before using a
ROTADISK Pneumatic Actuator.
ROTADISK Pneumatic Actuator
Type RD & RDF 2,5 – 160
BA3002 EN
Translation of Original Operating Manual
Installation
Operation
Maintenance

Table of Contents

Questions and Answers

  • K
    Kathryn KelleyAug 7, 2025
    What to do if there is a fault on the ROTADISK Pneumatic Actuator of Flowserve ROTADISK RDF Controller?
    • C
      Carol BrewerAug 7, 2025
      If you're experiencing a fault with the ROTADISK Pneumatic Actuator on your Flowserve Controller, begin by ensuring the control unit has a power supply. If not, connect it. Next, verify the compressed air supply is connected and that no vents are blocked. Following that, inspect the control air lines for leaks, obstructions, and proper routing. Finally, check that all control components are correctly connected and are switching in response to a control signal.
  • Q
    qfarrellAug 22, 2025
    What to do if there is a fault on the valve of Flowserve Controller?
    • B
      Brooke OsborneAug 22, 2025
      If you're encountering a fault on the valve of your Flowserve Controller, first, check the add-on between the pneumatic actuator and the valve for defects or incorrect installation; repair or correctly install if necessary. Also, the pneumatic actuator could be too weak, so design the control pressure or sparing package correctly. Finally, a defective transmission shaft/ball connection could be the cause, so repair the valve.

Summary

Safety Information

Grouped Safety Messages

Provides grouped general safety information for safe use of the actuator.

Qualified Personnel

Defines qualified personnel and their authorization for operational safety.

Personal Protective Equipment

Lists the essential personal protective equipment (PPE) required for operating personnel.

General Sources of Hazard;Residual Hazards

Describes general hazards and residual risks during intended and improper use.

Product Description

Installation

Installing ROTADISK Pneumatic Actuator on the Valve

Guidance on mounting the actuator onto the valve using standard interfaces.

Commissioning

Commissioning the ROTADISK Pneumatic Actuator

Step-by-step procedure for commissioning the pneumatic actuator.

Maintenance

Repair

Repairing the ROTADISK Pneumatic Actuator

Instructions for replacing worn seals, a common reason for leakages.

Troubleshooting Table

A table listing common problems, causes, and recommended solutions for the actuator.

Shutdown

Safety Information

Safety precautions for performing shutdown work on the actuator.

Shutting Down the ROTADISK Pneumatic Actuator

Steps for safely taking the pneumatic actuator out of operation.

Storage

Packing

Transport

Safety Information

Safety precautions for performing transport work on the actuator.

Flowserve ROTADISK RDF Specifications

General IconGeneral
BrandFlowserve
ModelROTADISK RDF
CategoryController