EasyManua.ls Logo

fluenta FGM 160 - Default Chapter; Table of Contents

fluenta FGM 160
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FGM 160 Operating Instructions
72.120.601
TABLE OF CONTENTS
1. Purpose ........................................................................................................................................... 3
2. Abbreviations/Definitions ............................................................................................................. 3
2.1 Abbreviations ......................................................................................................................... 3
2.2 Definitions .............................................................................................................................. 3
3. General Information ....................................................................................................................... 3
3.1 Hardware Description ............................................................................................................ 3
3.1.1 Electrical Connections .............................................................................................. 4
3.1.2 Power Supply ............................................................................................................ 4
3.1.3 Input Signals ............................................................................................................. 4
3.1.3.1 Ultrasonic Transducers ............................................................................. 4
3.1.3.2 Pressure and Temperature Transmitters .................................................. 5
3.1.4 Output Signals .......................................................................................................... 5
3.1.4.1 Modbus Communication (RS-485) ............................................................ 5
3.1.4.2 Foundation Fieldbus Output ...................................................................... 5
3.1.4.3 Current Loop Outputs ................................................................................ 5
3.1.4.4 HART Output ............................................................................................. 5
3.1.4.5 Pulse/Frequency Output ............................................................................ 5
3.1.5 Electronic Modules in FGM 160................................................................................ 6
3.1.5.1 Digital Signal Processing (DSP) Module ................................................... 6
3.1.5.2 Analog Front End (AFE) Module ............................................................... 6
3.1.5.3 Pressure & Temperature (P&T) Module .................................................... 6
3.1.5.4 Input/Output (I/O) Module .......................................................................... 6
3.1.5.5 Intrinsic Safety Barrier (IS Barrier) Module ............................................... 6
3.1.5.6 Surge Protection Module ........................................................................... 6
3.1.5.7 Local Display Module ................................................................................ 6
3.1.6 Non-Resettable Counter Function ............................................................................ 7
3.2 Firmware Description ............................................................................................................. 7
3.2.1 DSP Module .............................................................................................................. 7
3.2.2 P&T Module .............................................................................................................. 8
3.2.3 I/O Module ................................................................................................................ 8
3.3 Device Integrity ...................................................................................................................... 8
3.3.1 Self-Checking ........................................................................................................... 8
3.3.2 Watchdog Timer ....................................................................................................... 8
3.3.3 Flash Memory ........................................................................................................... 8
3.4 Configuration and Operating Software .................................................................................. 9
4. Operating Procedure ................................................................................................................... 10
4.1 Introduction .......................................................................................................................... 10
4.2 Power-Up Sequence ........................................................................................................... 10
4.3 Field Computer Configuration.............................................................................................. 10
4.4 Local Display Functions ....................................................................................................... 11
4.5 Error Check and Troubleshooting ....................................................................................... 12
4.5.1 Error Check with Local Display ............................................................................... 12
4.5.2 Error Check with UFM Manager ............................................................................. 13
5. References .................................................................................................................................... 13
6. Appendix I – System Configuration File .................................................................................... 14
7. Appendix II – Inserting settings from Client parameter list .................................................... 18

Other manuals for fluenta FGM 160