110 PLUS and 115
Users Manual
8
Rotary Switch Positions
Switch
Position
Measurement Function Model
Automatically selects ac or dc volts based on the sensed input with a low impedance input. 110 PLUS
Hz (button)
AC voltage from 0.06 to 600 V. 110 PLUS, 115
Frequency from 5 Hz to 50 kHz. 115
DC voltage from 0.001 V to 600 V. 110 PLUS, 115
AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.
110 PLUS, 115
Ω
Ohms from 0.1 Ω to 40 MΩ. 110 PLUS, 115
Continuity beeper turns on at <20 Ω and turns off at >250 Ω. 110 PLUS, 115
Diode Test. Displays OL above 2.0 V.
115
Farads from 1 nF to 9999 μF. 115
Hz (button)
AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display
flashes. >20 A, OL is displayed. DC-coupled.
Frequency from 45 Hz to 5 kHz.
115
DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display
flashes. >20 A, OL is displayed.
115
Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC amps are dc-coupled.