1550C/1555
Calibration Manual
2
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com
.
To register your product, visit http://register.fluke.com
.
To see, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals
.
Safety Information
A Warning identifies conditions and actions that pose hazard(s) to the user; A Caution
identifies conditions and procedures that could cause Product damage, equipment under
test damage, or permanent loss of data.
 Warning: Read before product use.
To prevent possible electrical shock, fire, or personal injury:
Read all safety Information before you use the product.
Before and after testing, confirm that the product does not
indicate the presence of a hazardous voltage, see Figure 2.
If the product beeps continuously and a hazardous voltage
is shown on the display, remove power from the circuit
under test or allow the installation capacitance to fully
discharge.
Use the product only as specified, or the protection supplied
by the product can be compromised.
Connect the common test lead before the live test lead and
remove the live test lead before the common test lead.
Do not disconnect the test leads before a test has been
completed and the test voltage at the terminals has returned
to zero. This ensures that any charged capacitance is fully
discharged.
Disconnect power and discharge all high-voltage capacitors
before you measure resistance or capacitance.
Do not work alone.
Do not use the product around vapor, or in damp or wet
environments.

Other manuals for Fluke 1550C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1550C and is the answer not in the manual?

Fluke 1550C Specifications

General IconGeneral
Display type-
Housing colorGrey, Yellow
Maximum voltage5000 V
AC voltage range250 - 5000 V
Operating altitude0 - 2000 m
Overload protectionYes
Storage temperature (T-T)-20 - 65 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 80 %
International Protection (IP) codeIP40
Battery technologySealed Lead Acid (VRLA)
Number of batteries supported1
Weight and Dimensions IconWeight and Dimensions
Depth277 mm
Width269 mm
Height160 mm
Weight3700 g