Measurement of Soil Resistivity
The soil resistivity is the geological and physical quantity for calculation and design of
earthing systems. The measuring procedure shown in Figure 10 uses the method
developed by Wenner (F. Wenner, A method of measuring earth resistivity; Bull. National
Bureau of Standards, Bulletin 12 (4), Paper 258, S 478-496; 1915/16).
1623-2 EARTH/GROUND TESTER
edv020.eps
Figure 10. Measurement of Soil Resistivity
1. Four earth stakes of the same length are positioned into the soil in an even line and
with the same distance "a" to each other. The earth stakes should not be hammered
in deeper than a maximum of 1/3 of "a".
2. Turn central rotary switch to position "R
E
4pole".
The instrument is to be wired according to picture and notices given on the display.
3. Push START.
4. Read out measured value R
E
.

Other manuals for Fluke 1623-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1623-2 and is the answer not in the manual?

Fluke 1623-2 Specifications

General IconGeneral
USB portYes
Control typeButtons, Rotary
CertificationIEC61326-1, CE
Housing colorBlack, Yellow
Display digits1999 digits
Measuring time6 s
Maximum voltage48 V
Display technologyLCD
Number of memory records1500
Storage temperature (T-T)-30 - 60 °C
Operating temperature (T-T)-10 - 50 °C
International Protection (IP) codeIP56
Battery sizeAA
Battery voltage1.5 V
Battery technologyAlkaline
Battery life (measurements)3000
Number of batteries supported6
Weight and Dimensions IconWeight and Dimensions
Depth187 mm
Width250 mm
Height133 mm
Weight1100 g

Related product manuals