EasyManuals Logo

Fluke 28 II Ex Calibration Information

Fluke 28 II Ex
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Digital Multimeter
Safety Information
3
Do not use and disable the Product if it is damaged.
Do not use the Product if it operates incorrectly.
Do not use the Product in damp or wet environments.
Keep fingers behind the finger guards on the probes.
Measure for hazardous voltage without the Low-Pass Filter.
WCaution
To prevent possible damage to the Meter or to the equipment
under test, follow these guidelines:
Disconnect circuit power and discharge all high-voltage
capacitors before you do resistance, continuity, diodes, or
capacitance tests.
Use the correct terminals, function, and range for all
measurements.
Before you measure current, check the fuses of the Meter.
(See Fuse Test.)

Other manuals for Fluke 28 II Ex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 28 II Ex and is the answer not in the manual?

Fluke 28 II Ex Specifications

General IconGeneral
Diode testYes
Product typeDigital multimeter
Product colorBlack, Red
Frequency range0.0005 - 199.99 kHz
DC current range0.0000001 - 10 A
DC voltage range0.0001 - 1000 V
Resistance range0.1 - 50000000 Ω
Measuring categoryCAT IV 600V
Placement supportedHandheld multimeter
Basic accuracy (frequency)0.005%
Basic accuracy (DC current)0.2%
Basic accuracy (DC voltage)0.05%
Temperature measurement range-200 - 1090 °C
Battery typeAAA
Power sourceBattery
Battery technologyAlkaline
Number of batteries supported3
Operating altitude0 - 2000 m
Maximum storage altitude10000 m
Operating relative humidity (H-H)0 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth198.1 mm
Width100 mm
Height6.35 mm
Weight698.5 g