EasyManua.ls Logo

Fluke 287 - DC Current Specifications

Fluke 287
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
287/289
Getting Started
10
DC Current Specifications
Accuracy
AC over DC, DC over AC, AC + DC
[1]
Function Range Resolution
DC
[1][3]
20 to 45 Hz 45 Hz to 1 kHz 1 to 20 kHz 20 to 100 kHz
[5]
500 μA 0.01 μA
0.075 % + 20 1 % + 20 0.6 % + 20 0.6 % + 20 5 % + 40
DC μA
[4]
5000 μA 0.1 μA
0.075 % + 2 1 % + 5 0.6 % + 5 0.6 % + 10 5 % + 40
50 mA 0.001 mA 0.05 % + 10
[6]
1 % + 20 0.6 % + 20 0.6 % + 20 5 % + 40 DC mA
[4]
400 mA 0.01 mA 0.15 % + 2 1 % + 5 0.6 % + 5 1.5 % + 10 5 % + 40
5 A 0.0001 A 0.3 % + 10 1.5 % + 20 0.8 % + 20 3 % + 40
[5]
Not Spec’d DC A
[2]
10 A 0.001 A 0.3 % + 2 1.5 % + 10 0.8 % + 10 3 % + 10
[5]
Not Spec’d
[1] AC+DC ranges are specified from 2 % to 140 % of range.
[2] 20 A for 30 seconds on, 10 minutes off. >10 A not specified.
[3] Add 20 counts in dual display ac over dc, dc over ac or ac+dc.
[4] 400 mA continuous; 550 mA for 2 minutes on, 1 minute off.
[5] Verified by design and type tests.
[6] Temperature coefficient: 0.1 X (specified accuracy)/ °C (<18 °C or > 28 °C)

Other manuals for Fluke 287

Related product manuals