Wireless Multimeter
Specifications
39
DC Voltage, Continuity, Resistance, Diode Test, and Capacitance
Function Range Resolution Accuracy
600.0 mV 0.1 mV
0.09 % + 2
6.000 V 0.001 V
0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
600 Ω 1 Ω Meter beeps at <25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ
0.5 % + 1
60.00 kΩ 0.01 kΩ
600.00 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode Test 2.000 V 0.001 V 1 % + 2
1000 nF 1 nF
1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF
[1]
1 μF
10 % typical
[1] In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.