Maximum overload ............................................ 10,000 A or rms x frequency < 400,000.
Amps rms is a true rms measurement (AC + DC)
Capture time ....................................................... 1, 3, 10, 30, 100 and 300 s
Sampling rate...................................................... 15.625 kHz
Digital Output
USB Interface to a PC
Power Log software for download, analysis and reporting
345 Upgrade Utility for installing a new firmware version
Logging Memory
Logging Areas..................................................... Three areas that can be used individually or combined into one large
area.
Averaging periods............................................... 1 s, 2 s, 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 15 min, and custom
Logging Times:
Volts and Current Mode
Average Time Logging Time (1 area) Logging Time (3 areas)
1 s 1 h 49 m 5 h 12 m
2 s 3 h 38 m 10 h 24 m
5 s 9 h 06 m 1 d 2 h 00 m
10 s 18 h 12 m 2 d 04 h 00 m
30 s 2 d 06 h 36 m 6 d 12 h 01 m
1 min 4 d 13 h 12 m 13 d 00 h 03 m
5 min 22 d 18 h 00 m 65 d 00 h 15 m
10 min 45 d 12 h 00 m 130 d 00 h 30 m
15 min 68 d 06 h 00 m 195 d 00 h 45 m
V & A Harmonics Mode
Average Time Logging Time (1 area) Logging Time (3 areas)
1 s 0 h 34 m 1 h 38 m
2 s 1 h 08 m 3 h 16 m
5 s 2 h 52 m 08 h 11 m
10 s 5 h 44 m 16 h 23 m
30 s 17 h 13 m 2 d 01 h 11 m
1 min 1 d 10 h 26 m 4 d 02 h 23m
5 min 7 d 04 h 10 m 20 d 11 h 25m
10 min 14 d 08 h 20 m 81 d 0 h 50m
15 min 21 d 12 h 30 m 121 d 13 h 15m
Single and Three Phase Power Mode
Average Time Logging Time (1 area) Logging Time (3 areas)
1 s 1 h 40 m 4 h 47 m
2 s 3 h 21 m 9 h 34 m
5 s 8 h 22 m 23 h 57 m
10 s 16 h 45 m 1 d 23 h 54 m
30 s 2 d 02 h 17 m 5 d 23 h 42 m
1 min 4 d 04 h 35 m 11 d 23 h 25 m
5 min 20 d 22 h 55 m 59 d 21 h 05 m
10 min 41 d 21 h 50 m 119 d 18 h 10 m