345
Calibration Manual
26
Power Check- Stage 1
Mode: Power
Input: 60/50Hz
Internal Accuracy: VA: ± 2.5% rdg ± 5 digits
W 1 phase < 2 kW + and - 0.08 kW
> 2 kW + and - 2.5 %rdg + and - 5 digits
W 3 phase < 4 kW + and - 0.25 kW
> 4 kW + and - 2.5 %rdg + and - 5 digits
VA 1 & 3 phase the same as single phase W (except SI unit is VA)
Calibrator Specification (k)W
Volts
(V)
Amps
(A)
Phase Shift
(°)
Min Nom Max
19 100 0.00 1820 1900 1980
21 100 0.00 2043 2100 2158
39 100 0.00 3798 3900 4003
41 100 0.00 3.95 4.10 4.25
390 100 0.00 37.98 39.00 40.03
410 100 0.00 39.5 41.0 42.5
Calibrator Specification (k)VA
Volts
(V)
Amps
(A)
Phase Shift
(°)
Min Nom Max
19 100 0.00 1848 1900 1943
21 100 0.00 2042 2100 2158
39 100 0.00 3797 3900 4003
41 100 0.00 3.95 4.10 4.25
390 100 0.00 38.00 39.00 40.00
410 100 0.00 39.5 41.0 42.5
Calibrator Specification PF
Volts
(V)
Amps
(A)
Phase Shift
(°)
Min Nom Max
19 100 0.00 0.998 1.00 1.00
21 100 0.00 0.998 1.00 1.00
39 100 0.00 0.998 1.00 1.00
41 100 0.00 0.998 1.00 1.00
390 100 0.00 0.998 1.00 1.00
410 100 0.00 0.998 1.00 1.00