7-1
Chapter 7
Specifications
Safety and Compliances
Maximum voltage between any terminal and earth
ground.
1000 V ac/dc
Compliances Complies with ANSI/ISA-S82.01-94, CSA C22.2 No 1010.1-92 to
1000 V Overvoltage Category III, Polution Degree 2 *
Certifications (Iisted and pending) CSA per standard CSA/CAN C22.2 No. 1010.1-92
UL per standard UL 3111 (pending)
TÜV per standard EN 61010 Part 1-1993 (pending)
Surge Protection 8 kV peak per IEC 1010.1-92
WFuse Protection for mA or µA inputs
WFuse Protection for A input
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse
11 A, 1000 V FAST Fuse
Markings P, ) (UL and TÜV pending)
* CAT III: OVERVOLTAGE (Installation) Category III, Pollution Degree 2 per IEC1010-1 refers to the level of Impulse
Withstand Voltage protection provided. Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.