Users Manual
7-12
Input Characteristics
Function Input Impedance (Nominal)
Volts, mV 10 M, < 100 pF
Common Mode Rejection Ratio Normal Mode Rejection
DC Volts, mV >100 dB -dc, 50 Hz, or 60 Hz ±0.1% >90 dB at 50 Hz, or 60 Hz ± 0.1%
AC Volts, mV > 90 dB dc to 60 Hz
Full-Scale Voltage
Open Circuit Test Voltage To 5 M 30 M + nS
Ohms < 5 V 500 mV 3.1 V
Diode Test < 5 V 3.1000 V
Typical Short-Circuit Current
500 5 k 50 k 500 k 5 M 30 M
Ohms 100 µA 100 µA 10 µA 1 µA 0.1 µA 0.1 µA
Diode Test 0.8 mA typical