Digital Multimeter 
 
Supported SCPI Commands 
  29 
Table 11. Math Command Summary 
Command Description 
CALCulate 
 :AVERage 
  :MINimum? 
  :MAXimum? 
  :AVERage? 
  :COUNt? 
 :DB 
  :REFerence  
       {<value>|MINimum|MAXimum}   
  :REFerence? 
 :DBM 
  :REFerence  
       {<value>|MINimum|MAXimum} 
  :REFerence? 
 :FUNCtion  
  {NULL|DB|DBM|AVERage|LIMIt} 
 :FUNCtion? 
 :KMATh 
    :STATe { on|off} 
  :MMFactor{<value>} 
  :MMFactor? 
  :MBFactor{<value>} 
  :MBFactor? 
  :MUNits{<name>} 
  :MUNits? 
 :LIMit 
  :LOWer{<value>|MINimum|MAXimum} 
  :LOWer? 
  :UPPer{<value>|MINimum|MAXimum} 
  :UPPer? 
 :NULL 
  :OFFSet {<value>|MINimum|MAXimum} 
  :OFFSet? [MINimum|MAXimum] 
 :STATe {ON|OFF} 
 :STATe? 
DATA 
  :FEED RDG_STORE, {“CALCulate”|” ”} 
 :FEED? 
Path to the math functions 
  Path to MIN-MAX function 
    Retrieves the recorded minimum value 
    Retrieves the recorded maximum value 
    Retrieves the recorded average value 
    Retrieves the number of readings during MIN-MAX run
  Path to DB function 
    Store relative value in relative register 
 
    Retrieves the relative value from the relative register 
  Path to DBM function 
    Select dBm reference value 
 
    Retrieves the present dBm reference value 
  Sets the math function 
 
  Retrieves the present math function 
Path to math functions 
  Disables/enables mx+b calculations 
  Sets the value of “m” for mx+b 
  Reads the value of “m” for mx+b 
  Sets the value of “b” for mx+b 
  Reads  the value of “b” for mx+b 
  Sets the units name for mx+b 
  Reads the units name for mx+b 
Path to limit testing function 
    Set the lower limit for limit testing 
    Retrieves the lower limit 
    Set the upper limit for limit testing 
    Retrieves the upper limit 
  Path to null function 
    Sets the offset value 
    Retrieves set or maximum or minimum offset value. 
  Disable/enable selected math function 
  Retrieves the state of the math function 
Path to storing readings taken with INITiate command 
  Enables/disables storing of INITiate readings 
  Retrieves state of storing INITiate readings 
Table 12. MEASure Command Summary 
Command Description 
MEASure[:SCALar] 
 :CAPacitance?  
 [{<range>|MIN|MAX|DEF}[{,<resolution>|MIN|MAX|DEF}]] 
 :CONTinuity? 
 :CURRent 
  :DC? 
    [{<range>|MIN|MAX|DEF}[, {<resolution>|MIN|MAX|DEF}]]
  :AC? 
Path to measure control 
  Preset and make capacitance 
 measurement 
  Make a continuity measurement   
Path to measure current 
    Make a dc current measurement 
 
    Make an ac current measurement