Specifications
Range ..................................................................... 2500 A ac
Resolution ............................................................. 0.1 A for 0 A to 1000 A; 1 A for 1000 A to 2500 A
Accuracy ................................................................ 3 % ±5 digits (45 Hz to 500 Hz)
Crest Factor (50 Hz/60 Hz).................................... 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. >2
Frequency .............................................................. 45 to 500 Hz 0.5 % ±5 digits
LCD w/Backlight .................................................... 3 ½ digits
Log Rate/Interval ................................................... 1 second to 1 hour adjustable by PC, default, 1 minute
Battery Type .......................................................... 2 AA, NEDA 15 A, IEC LR6
Battery Life ............................................................ 370 hours
Memory .................................................................. Record a maximum of 65,000 readings
Radio Frequency Communications .................... 2.4 GHz ISM Band
Radio Frequency Communication Range .......... 20 m (65.61 ft)
Radio Frequency Certification ............................. FCC: T68-FBLE; IC: 6627A-FBLE
Operating Temperature ........................................ -10 °C to +50 °C (14 °F to 122 °F)
Storage Temperature ............................................ -40 °C to +60 °C (-40 °F to 140 °F)
Operating Humidity ............................................... 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
(90 % at 95 °F, 75 % at 104 °F, 45 % at 122 °F)
Operating Altitude ................................................. 2,000 m (6,562 ft)
Storage Altitude .................................................... 12,000 m (39,370 ft)
Temperature Coefficient ....................................... Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Add 0.1 X (specified accuracy)/ °F (<64.4 °F or >82.4 °F)
Safety ..................................................................... IEC 61010-1, Pollution Degree 2
Electromagnetic Environment ............................. IEC 61236-1, Portable
Electromagnetic Compatibility ............................ Radio Frequency Emissions, IEC CISPR 11: Group 1, Class A.
Group 1 have intentionally generated and/or use conductively coupled
radio-frequency energy which is necessary for the internal functioning
of the equipment itself.
Class A equipment is suitable for use in non-domestic locations and/or
directly connected to a low-voltage power supply network. Class A
equipment may have potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted as well as
radiated disturba
nces.
Applies to use in Korea only. .............................. Class A Equipment (Industrial Broadcasting & Communication
Equipment)
[1]
[1] This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Ingress Protection (IP) rating............................... IP42
Size ......................................................................... 165 mm x 64 mm x 36 mm (6.5 in x 2.5 in x 1.4 in)
Weight .................................................................... 0.283 kg (10 oz)
Jaw Opening .......................................................... 10 in coil