22
Test Result Possible Cause of Result
FAIL or PASS* General rule: troubleshoot NEXT problems rst. This
normally corrects any ACR-F (ELFEXT) problems
Service loops with many tightly coiled windings
ACR-F and PS ACR-F
(older names: ELFEXT and PSELFEXT)
Test Result Possible Cause of Result
FAIL or PASS* Excessive cable length
Poor connection due to oxidized contacts
Poor connection due to marginally attached conductors
Thinner gauge cable
Incorrect patch cord type