MicroMapper
User’s Manual
6
MICROMAPPER Tests
1. Slide the switch on the right side to the Cable
position to turn M
ICROMAPPER on.
2. Connect one end of the cable to be tested to the
M
ICROMAPPER’s RJ45 jack.
3. Connect the other end of the cable to the
M
ICROMAPPEr Remote’s RJ45 jack.
4. Press (TEST) to view the results.
5. The horizontal LEDs indicate the cable’s integrity
status.
• Green: Pair or Shield is good
• Green flashing: Pair or Shield is faulty
• No light: Pair is open or cable is not shielded
The vertical LEDs indicate the wiring faults and a
low battery status. Wiring faults are: SHORT,
REVERSED, MISWIRE, SPLIT PAIRS.
6. To find out a fault on a specific pair, use
M
ICROMAPPER’s diagnostic feature.
7. Press and hold
(TEST) for more than 2 seconds.
M
ICROMAPPER will scan each pair and the shield
pausing and flashing each green LED separately. If
a faulty pair is detected, the corresponding fault
status will blink in red.
Note
Push the Remote Terminator onto the
MicroMapper until it snaps into position. This
configuration allows you to conveniently test
patch cables.