MicroMapper™
Battery
5
Battery
MICROMAPPER requires four 1.5 AAA batteries. IEC :
LR03. Others : AAA, E92, 4003; JIS : AM 4 ; ANSI : 24A;
1.5 Volt (nominal).
atx03s.bmp
The Battery LED will light up when MICROMAPPER
detects a low battery condition. Using MICROMAPPER
with a low battery may affect the test accuracy. If
M
ICROMAPPER is stored for more than a month, the
battery should be removed.
MICROMAPPER’s Toner Operation
1. Slide the switch on the right side of MICROMAPPER
to the Toner position.
2. Connect the cable to the M
ICROMAPPER’s RJ45 jack.
(To send a tone into a patch panel, connect one
end of the included patch cord to the
M
ICROMAPPER’s RJ45 jack and the other end to a
jack on the panel.)
3. To generate tone 1, press and quickly release the
(TEST) button.
4. To generate tone 2, press and hold the
(TEST)
button for two seconds.
5. Use the M
ICROPROBE to trace the connected cable.
The signal reception is strongest near the cable
under test.
6. Slide the switch on the right side to the Off
position to discontinue the tone. (Always power
the unit off to prevent battery drain.)